Display method : 4-digit 7-segment LED
Character height : 14.2mm
Max. display Range : -1999 to 9999
Measurement : AC voltage, Frequency
Input specification : 0-500V, 0-250V, 0-110V, 0-50V, 0-20V, 0-10V, 0-2V, 0-1V
Power supply : 100-240VAC~ 50/60Hz
Approval :

...
Display method 4-digit 7-segment LED
Character height 14.2mm
Max. display Range -1999 to 9999
Measurement AC voltage, Frequency
Input specification 0-500V, 0-250V, 0-110V, 0-50V, 0-20V, 0-10V, 0-2V, 0-1V
AC Measurement Average value (AVG), Root mean square value (RMS)
Power supply 100-240VAC~ 50/60Hz
Output_Main Output(Comparative Value) NPN open collector (HI, GO, LO)
Output_Sub Output(Display Value) RS485 communication
Approval  
Display accuracy • 23℃±5℃ – F.S. ±0.3% rdg±3-digit (frequency: F.S.±0.1% rdg±2-digit)
F.S +0.3% rdg ±3-digit max. only for 5A terminal
• -10℃ to 50℃ – F.S.±0.5% rdg±3-digit
Max. allowable input 110% F.S. for each measured input range
A/D conversion method Practical oversampling using successive approximation ADC
Sampling cycle 16.6ms
Frequency measurement Measurement range: 0.100 to 9999Hz(variable by decimal point position)
Hold function Includes (external hold function)
Environment_Ambient temperature -10 to 50℃, storage: -20 to 60℃
Environment_Ambient humidity 35 to 85% RH, storage: 35 to 85% RH
Insulation type Double insulation or reinforced insulation(mark: , dielectric strength between the measuring input part and the power part: 1kV)
Weight Approx. 326g (approx. 211g)

※To measure the current over DC5A, please select DV type because the shunt should be used.
※In case of selecting frequency display, no output will be provided even if it is output support models.
(main output, sub output and RS485 communication output)
※The weight includes packaging. The weight in parenthesis is for unit only.
※Environment resistance is rated at no freezing or condensation.